Staircase automation, 5 functions | connection of 3 buttons

staircase timer / staircase time relay with 5 time functions and 10 time ranges, for mounting on DIN rail TH-35, for indoor use only
item number: 10044279
23.99
 
incl. VAT excl. shipping cost
letter standard delivery
available
shipping 1 to 4 days**
 
- housing: plastic
- mounting: DIN rail TH-35
- space requirement: 1 division unit
- contact material: AgSnO2
- suitable for use with inductive loads
- number of consumers (buttons): 3
- rated voltage: 250V AC
- power: 16A
- switching capacity: 1W - 4000W
- switching frequency: max. 600 cycles/h
- contact resistance: = 100mOhm
- switching frequency: > 0.5 x 10^5
- mechanical resistance (cycles): > 3 x 10^7
- adjustment knob for time function, time range and time setting (extra time)
- 5 time functions, 10 time ranges
- time Functions: ON, OFF, AUTO, R, Wi + Extra Time
- Explanation of the individual functions can be found under "Note".
- time ranges: 1s, 10s, 20s, 30s, 1min, 1.5min, 2min, 3min, 5min, 10min.
- accuracy of time setting: ± 5%
- green LED status display U for voltage and time measurement (flashing)
- yellow LED status indicator R for the status of the output relay ON/OFF
- connection via screw terminals
- connection cable cross-section: max. 2.5mm²
- dimensions: approx. 64.6x17.5x90mm (h-w-d)
- weight: about 66g
- working temperature: -20°C ... +50°C
- storage humidity: < 85%
- protection class: IP20
- all details according to the manufacturer

Explanation of time functions
ON: permanent activation of the contact
Switching on the supply voltage U causes the contact R to be permanently switched on. Switching the control contact S on and off has no effect on the status of the contact R.

OFF: permanent deactivation of the contact
Switching on the supply voltage U does not cause any change in the status of the relay - the contact R remains permanently switched off. Switching control contact S on and off has no effect on the status of contact R.

AUTO: switch on at set time
Every time the supply voltage U is switched on or every time the control contact S is closed when the supply voltage U is switched on, the contact R is switched on immediately for an adjustable time T. After the time T has been measured, the contact R is switched off. The opening and closing of the control contact S during the measurement of the time T does not affect the implemented function. If the AUTO function is enabled in the ”Extra Time” mode, after measuring the time T, the contact R is switched off for 1s and then switched on again for 10s. After measuring the time of 10s, the contact R is switched off.

R: Shutdown delay
The input of the timing relay is permanently supplied with the voltage U. Closing the control contact S leads to immediate switching on of the execution relay R. Opening of the control contact S counts the set delay time for switching off the execution relay R. After measuring the time T, the execution relay R switches off. If the control contact S is closed before the time T has elapsed, then the previously measured time is reset to 0 and the execution relay remains switched on. The delay of the execution relay R begins with further opening of the control contact S. If the R function is enabled in the ”Extra Time” mode, after the counting of the time T, the contact R is switched off for 1s, and then it is switched on again for 10s. After measuring the time of 10 s, the contact R is switched off.

Wi: controlled switching on for a set time with switching off function
The input of the timing relay is permanently supplied with the voltage U. Closing the control contact S leads to the immediate switching on of the execution relay R for the set time T. After the time T counts, the execution relay R turns off. The execution relay R is switched on again for the time T by closing the control contact S again. If the control contact S closes again during the measurement of the time T, the execution relay is switched off immediately and the measured time is deleted. The opening of the control contact S during the measurement of the time T does not affect the implemented function. If the Wi function is enabled in the ”Extra Time” mode, after measuring the time T, the contact R is switched off for 1s and then switched on again for 10s. After measuring the time of 10s, the contact R is switched off.

Safety instructions and important information
- Connection or installation must be performed only by qualified staff.
- Never exceed the maximum connected load.
- No assembly near or even on combustible materials such as wood, etc.
- The 230V components must be connected with at least 1.5mm² cable.
- Please be aware of the appropriate health and safety regulations within your country.
- No installation on or in the vicinity (50cm) of flammable materials (flash point >200°C).
- Turn off or disconnect from the main circuit before starting to work. Otherwise there is a danger to LIFE.
- A professional electrician should check connection or installation before switching on power again and operating the device.

* all prices including VAT and excluding shipping cost; minimum order 10 euros
** Valid for deliveries for standard shipping within Germany. Delivery times for other countries and information on the calculation of delivery, see here.
highlight-led
  • Payment via bank transfer
LED-FAQ
contact
about us